搜索澳门新萄京8522关键词找到我们澳门新萄京8522(www.8522.com)!

澳门新萄京8522-新闻资讯>行业咨询>分析新萄京8522有哪些技术要求!

其他案例

分析新萄京8522有哪些技术要求!

来源:     发表日期: 2018-11-13 16:53:54     浏览次数:次    
  1、新萄京8522系统采用工厂预制,应包括锚固体、加固吊杆、抗震连接构件及抗震斜撑组成。现场采用装配式安装,并根据现场使用环境,表面进行防腐处理,避免使用中产生粉尘或油漆老化脱落,以保证洁净度及方便后期维护。
  1. The anti-seismic bracket system is prefabricated by factory, which should include anchor, reinforced suspender, anti-seismic connecting member and anti-seismic brace. Assembled installation is adopted on site, and anti-corrosion treatment is carried out on the surface according to the working environment. Dust or paint aging and peeling are avoided in use, so as to ensure cleanliness and facilitate later maintenance.
  U型槽钢为冷弯成型槽钢,截面尺寸为41×41mm、41×62mm等,长度为3m或6m的标准型材,钢材材质为Q235及以上级别,槽钢壁厚不小于2.5mm。
  U-shaped channel steel is Cold-Formed Channel steel. Its cross-section size is 41 *41m m, 41 *62m m, and its length is 3 m or 6 m. The steel material is Q235 or above. The wall thickness of channel steel is not less than 2.5m M.
  2、新萄京8522U型槽钢内缘须带齿牙,且齿牙深度不小于1毫米,并且所有配件的安装依靠机械咬合实现,严禁任何以配件的摩擦作用来承担受力的安装方式,以保证整个系统的可靠连接。
  2. The inner edge of U-shaped channel steel of anti-seismic bracket must have teeth, and the depth of teeth is not less than 1 mm, and the installation of all accessories depends on mechanical occlusion. It is strictly forbidden to install any way to bear the force by the friction of accessories, so as to ensure the reliable connection of the whole system.
  3、澳门新萄京8522需具有:第三方认证的建筑机电抗震支撑系统深化设计软件,保证支吊架的力学安全,并能提交方案及计算书。
  3. Seismic bracket manufacturers need to have: third-party certified seismic bracing system of construction machinery to deepen the design software, to ensure the mechanical safety of the bracket and hanger, and to submit the program and calculation.
  4、新萄京8522系统,必须具备以下检测报告,以确保使用安全:
  4. Aseismic support system must have the following test reports to ensure safety:
  管束的力学性能检测报告,确保管束在地震作用下的荷载安全。
  The mechanical performance test report of the tube bundle ensures the load safety of the tube bundle under the earthquake action.
  抗震连接构件的力学性能检测报告,确保抗震连接构件的在地震作用下的荷载安全。
  The mechanical performance test report of the aseismic connection member ensures the load safety of the aseismic connection member under the earthquake action.
  新萄京8522整体防火性能检测报告,确保新萄京8522在发生火灾情况下的防火时效。
  The overall fire performance test report of the anti-seismic bracket ensures the fire aging of the anti-seismic bracket in case of fire.
  抗震支吊架整体地震模拟测试报告,且模拟试验不得低于8度(0.30g)罕遇地震作用工况。
  The whole seismic simulation test report of the anti-seismic support and hanger should not be less than 8 degrees (0.30g) rare earthquake conditions.
  新萄京8522的技术要求有哪些?
  What are the technical requirements of the seismic support?
  5、表面处理:
  5. Surface treatment:
  抗震连接构件表面应采用锌铬涂层进行处理,并符合《锌铬涂层技术条件》GB/T18684-2002标准要求。
  Zinc-chromium coating should be used on the surface of seismic connection components, which meets the requirements of GB/T 18684-2002 Standard of "Technical Conditions for Zinc-chromium Coating".
  新萄京8522可在地震中给予机电各系统充分保护,可用于抵抗来自水平及垂直方向的地震力的破坏。根据所保护机电系统的不同,抗震支吊架可分为管道新萄京8522系统、风管抗震系统和电气抗震系统。
  Earthquake-resistant brackets can provide adequate protection to mechanical and electrical systems during earthquakes, and can be used to resist damage from horizontal and vertical seismic forces. According to the different mechanical and electrical systems protected, the anti-seismic brackets can be divided into pipeline anti-seismic bracket system, wind pipe anti-seismic system and electrical anti-seismic system.
澳门新萄京8522
  6、新萄京8522分类及布置原则
  6. Classification and layout principles of seismic support
  管道抗震加固侧向间距要求为:沟槽连接管道、焊接钢管、钎焊铜管等刚性材质的管线.横向吊架间距大不得超过12m;HDPE等非刚性材质的管线,横向吊架间距最大不得超过6m。
  The lateral spacing requirements for seismic reinforcement of pipelines are as follows: pipelines with rigid materials such as grooved connection pipes, welded pipes, brazed copper pipes, etc. The maximum spacing of transverse hangers shall not exceed 12 m; pipelines with non-rigid materials such as HDPE, the maximum spacing of transverse hangers shall not exceed 6 m.
  管道抗震加固纵向间距要求为:沟槽连接管道、焊接钢管、钎焊铜管等刚性材质的管线,纵向吊架间距大不得超24m;HDPE等非刚性材质的管线,横向吊架间距大不得超过12m。
  Longitudinal spacing requirements for seismic reinforcement of pipelines are: grooved connection pipelines, welded steel pipes, brazed copper pipes and other rigid material pipelines, longitudinal suspension spacing should not exceed 24m; HDPE and other non-rigid material pipelines, transverse suspension spacing should not exceed 12m.
  7、风管新萄京8522的布置原则
  7, the layout principle of wind pipe seismic support
  普通刚性风管侧向抗震吊架的大间距为9m,普通刚性风管纵向抗震吊架的较大间距为18m。
  The maximum spacing of the lateral anti-seismic suspension of the common rigid duct is 9m, and that of the longitudinal anti-seismic suspension of the common rigid duct is 18m.
  玻璃纤维、塑料和其他非刚性材质风管的侧向抗震吊架,最大间距为4.5m.纵向最大间距为9m。
  Lateral anti-seismic hangers of glass fiber, plastic and other non-rigid ducts have a maximum spacing of 4.5 m and a maximum longitudinal spacing of 9 M.
  8、电气新萄京8522的布置原则
  8. The layout principle of electrical seismic support.
  刚性电气线管、线槽及桥架侧向抗震最大间距不得超过12m,纵向抗震最大间距不得超过24m。
  The maximum lateral seismic spacing of rigid electrical pipes, grooves and bridge frames shall not exceed 12 m, and the maximum longitudinal seismic spacing shall not exceed 24 M.
  非刚性材质电气线管、线槽及桥架横向抗震最大间距不得超过6m,纵向最大间距不得超过12m。
  The maximum transverse and longitudinal spacing of non-rigid electrical pipes, grooves and bridges shall not exceed 6m and 12m respectively.
  如果您有抗震技术或抗震产品的需要请及时联系澳门新萄京8522:/,我们将竭诚为您服务!
  If you have anti-seismic technology or products, please contact the manufacturer of anti-seismic brackets in time: /, we will serve you wholeheartedly!